Power And Wiring; Power Cord - Emerson Quiet Kool 18 SEER Serie Manual Del Usuario

Ocultar thumbs Ver también para 18 SEER Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

Power and Wiring

Connecting of the Cable
Indoor Unit
Connect the power cord to the indoor unit by connecting
the wires to the terminals on the control board individually
in accordance with the outdoor unit connection.
Note: For some models, it is necessary to remove the cabinet to
connect to the indoor unit terminal.
Outdoor Unit
1) Remove the
cable cross board
the screw. Connect the wires to the terminals on the
control board individually as follows.
2) Secure the power cord onto the control
board with cable clamp.
3) Reinstall the
cable cross board
with the screw.
4) Use a recognized circuit breaker between the power
source and the unit. A disconnecting
disconnect all supply lines must be fitted.
Caution:
1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of
wiring, refer to the circuit diagram posted on the inside of the access door .
2. Comfirm that the cable thickness is as specified in the power source specification.
3. Check the wires and make sure that they are all tightly fastened after cable connection.
4. Be sure to install an earth leakage circuit breaker in wet or moist areas.
Cable Specifications
capacity(Btuh)
9K-12K(208/230V)
18K(208/230V)
24K-36K(208/230V)
9K,12K(115V)
Attention:
The plug must be accessible even after the installation of the appliance in case there is a need to
disconnect it. If not possible, connect appliance to a double-pole switching device with contact
separation of at least 3 mm placed in an accessible position even after installation.
from the unit by loosening
to the original position
device to adequately

Power cord

Normal cross-
Type
sectional areas
SJ TW
3X16 AWG
SJ TW
3X14 AWG
SJ TW
3X12 AWG
SJ TW
3X14 AWG
16
Front panel
Terminal (inside)
Indoor unit
Outdoor unit
The figures in this manual are based on the external
view of a standard model. Consequently, the shape
may differ from that of the air conditioner you have
selected.
Power connecting cord
Normal cross-
Type
sectional areas
SJ TW
4X18 AWG
SJ TW
4X18 AWG
SJ TW
4X18 AWG
SJ TW
4X18 AWG
Cabinet
Chassis
Cable Cross Board
Wire Hole

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

9 000 btu12 000 btu18 000 btu24 000 btu

Tabla de contenido