Start-Up; Test Operation - Emerson Quiet Kool 18 SEER Serie Manual Del Usuario

Ocultar thumbs Ver también para 18 SEER Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions

Start-up

Test Operation

Perform test operation after completing gas leak and electrical safety check.
1.Turn on electrical disconnect to outdoor unit.
2.Push the "ON/OFF" button on Remote Controller to begin testing.
3.Push MODE button, select COOLING, HEATING, FAN mode to confirm all functions.
System Checks
1.Conceal refrigerant pipes where possible.
2.Make sure drain hose slopes downward along entire length.
3.Ensure all refrigerant pipes and connections are properly insulated.
4.Fasten pipes to outside wall, when possible.
5.Seal and weatherproof wall hole which the interconnecting wires and refrigerant pipes pass through.
Indoor Unit
1.Do all Remote controller's buttons function properly?
2.Do the display panel lights work properly?
3.Does the swing louver function properly?
4.Does the drain work?
Outdoor Unit
1.Push the mode button to COOL and adjust the room setting to 61
compressor time guard. Does compressor and outdoor fan turn on in cooling mode?
2.Push the mode button to HEAT and adjust the room setting to 85 ℉(30℃) deg. wait up to 3 minutes for
compressor time guard. Does compressor and outdoor fan turn on in heat mode?
℉(16℃
19
deg. wait up to 3 minutes from
)