The device MAT-130 is intended for use in the electromagnetic environment specified below.
The customers or the user of the device MAT-130 should assure that it's used in such an environment.
Immunity Test
Electrostatic discharge
(ESD)
EN 61000-4-2
Electrical fast
transient / burst
EN 61000-4-4
Surge
EN 61000-4-5
Loss of voltage, brief
5%U
voltage interruptions
and variations
EN 61000-4-11
Magnetic field
EN 61000-4-8
Note U
is the value of the power supply voltage
T
The device MAT-130 is intended for use in the electromagnetic environment specified below.
The customers or the user of the device MAT-130 should assure that it's used in such an environment.
Immunity Test
Conducted Immunity
EN 61000-4-6
Radiated Immunity
EN 61000-4-3
Note 1: At 80 MHz and 800 MHz the interval with the highest frequency is applied
Note 2: These guide lines may not be applicable in all situations. The electro-magnetic propagation is influenced by the
absorption and by reflection from buildings, objects and people.
a) The field intensity for fixed transmitters such as the base stations for radiotelephones (mobile and cordless) and
terrestrial mobile radio, amateur radio devices, radio AM and FM transmitters and TV transmitters can not be theoretically
and accurately foreseen.
To establish an electro-magnetic environment generated by fixed RF transmitters, an electro-magnetic study of the site
should be considered. If the field intensity measured in the place where the device will be used surpasses the above
mentioned applicable level of conformity, the normal functioning of the device should be monitored. If abnormal
performance arises, additional measures such as changing the device's direction or positioning may be necessary.
b) The field intensity on an interval frequency of 150 kHz to 80 MHz should be less than 3 V/m.
Guidance and manufacturer's declaration – Immunity Emissions
Level indicated by
Compliance
the EN 60601-1-2
± 6kV on contact
The device
± 8kV in air
doesn't change
± 2kV power supply
The device
lines
doesn't change
± 1kV for input /
output lines
± 1kV differential
The device
mode
doesn't change
(>95% dip U
)
T
T
for 0.5 cycle
40%U
(>60% dip
T
U
) for 5 cycle
T
70%U
(>30% dip
T
U
) for 25 cycle
T
<5%U
(>95% dip
T
U
) for 5 sec
T
3A/m
The device
doesn't change
Guidance and manufacturer's declaration – Immunity Emissions
Level indicated by
Compliance
the EN 60601-1-2
3Vrms 150kHz to
V
1
80Mhz
(for non life-
supporting devices)
3V/m 80MHz to
E
1
2.5GHz
(for non life-
supporting devices)
Electromagnetic environments - guidance
Level
Floors should be wood, conceret or ceramic tile. If
floors are covered with synthetic material, the relative
its state
humidity should be at least 30%.
Mains power quality should be that of a typical
commercial environment or hospital
its state
Mains power quality should be that of a typical
commercial environment or hospital
its state
-
Mains power quality should be that of a typical
commercial environment or hospital If the user of the
MAT-130 device request that the appliance operates
continuously, the use of a continuity unit is
recommended.
The power frequency magnetic field should be
measured in the intended installation location to
its state
assure that it's sufficiently low.
Electromagnetic environments - guidance
level
= 3 V rms
The portable and mobile RF communication devices, including
cables, must not be used closer to the device MAT-130, than
the separation distance calculated by the equation applicable
to the transmitter frequency. Recommended separation
distance
= 3 V / m
d = [3.5 / V
]
1
d = [12 / E
]
1
d = [23 / E
]
1
Where P is the maximum nominal output voltage of the
transmitter in Watt (W) depending on the manufacturer of the
transmitter and the recommended separation distance in
metres (m). The intensity of the field from the fixed RF
transmitters, as determined by an electro-magnetic study of
the site
, could be lower than the level of conformity of each
a)
frequency interval
proximity to devices identified by the following symbol:
13
P
P
from 80 MHz to 800MHz
P
from 800 MHz to 2.5 GHz
. It is possible to check for interference in