Safety shoes with good ankle support and toe protection;
•
Hearing protection during continuous use of pneumatic systems.
2.5
Safety regulations with respect to the equipment
2.5.1
General
•
Position the pump during use at a safe distance of at least 1 metre from buildings and constructions.
2.5.2
Drive with air power motor
•
Do not connect compressed air if any oil or grease is present. Oil and grease is explosive in the
vicinity of compressed air.
•
Do not stay in line with the air stream.
•
Do not use other gases or liquids to drive the air motor.
•
Do not use a higher air pressure than the maximum of 8 bar.
2.5.3
Hose
•
Do not allow heavy objects to fall on the hose.
•
Keep the hose away from the working area of the tool.
•
Prevent damage to the hose.
•
Do not allow dual hoses to twist.
•
Avoid kinks in the hose; never bend the hose past its minimum bending radius.
•
Never use the hose to carry, pull or move the tool or pump or to keep them in position.
•
Replace the hose no later than 10 years after the date of manufacture, regardless of its use and
external appearance.The date of manufacture is part of the test code (yymm****).
2.6
Safety regulations with respect to the operation of the system
•
Make a risk assessment of the procedure before you start work (EN-ISO 12100).
•
Keep bystanders at a distance and be extra careful in the vicinity of people and animals.
•
Make sure the work area is clearly laid out and has good lighting.
•
Avoid stress and work in a structured way. This reduces the risk of errors, combinations of dangers
and accidents.
•
Before use, check the equipment for damage. Do not use the equipment if it is not in good condition
and consult your Holmatro dealer.
•
Stand on a stable base.
•
Hold the equipment only by its carrying handle. Never use any part of the hose as carrying handle.
•
During operation, never get between the object and the equipment.
•
Monitor the situation of the equipment and the structure continuously while using the equipment.
•
Parts of an object that could fly off must be secured.
•
Never couple or uncouple couplers while the system is under pressure.
•
Use only genuine Holmatro accessories and ensure that they have been attached correctly.
•
Make sure that parts of the body never come between moving parts. There is a risk that parts of the
body may be crushed or cut.
•
Stop immediately if the system makes strange noises or displays aberrant behaviour.
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person who is injected with oil for medical
help. Give a specification of the oil to the medical staff.
•
Return inactive equipment immediately to the tool station.
•
Always adhere to the safety regulations that apply to other equipment that is used in the operation.