Your air compressor was designed for 100% continuous
duty operation with the use of Ingersoll-Rand synthetic
compressor lubricant and 60% continuous duty operation
with the use of petroleum lubricant. In other words, synthetic
lubricant allows the compressor to pump continuously
without cycling. Petroleum lubricant limits the compressor
to a maximum of 36 minutes of pumping time per hour. The
compressor should not cycle more than 10 times per hour.
NORMAL START-UP
1.
Set the pressure switch lever to "OFF"
Pressure Switch Lever
2.
Close the regulator by pulling the adjustment dial out
and turning it fully counterclockwise (A). Push the dial in
when the knob will no longer turn.
Regulator
3.
Attach hose and accessory.
4.
Move the pressure switch lever to "ON/AUTO". The unit
will start.
5.
Allow tank pressure to build. The motor will stop when
tank pressure reaches cut-out pressure.
6
RELEASED 26/Jan/2020 20:37:54 GMT
OPERATION
When the receiver tank pressure drops below the
factory pre-set minimum, the pressure switch resets
and restarts the unit .
6.
Adjust the regulator to the desired secondary
pressure by pulling the adjustment dial out and
turning it clockwise (B) to increase the pressure or
counterclockwise (A) to decrease the pressure. Push the
dial in when the desired pressure is reached.
NOTICE
SHUTDOWN
1.
Set the pressure switch lever to "OFF".
2.
Close the service valve fully.
3.
Remove the air tool or accessory.
4.
Slowly open the service valve to bleed air pressure down
to 20 psig.
5.
Slowly open the manual drain valve at the bottom of the
tank to drain all condensate (water).
6.
Close the drain valve and the service valve for the next
use.
7.
Wrap the power cord securely around the handle.
8.
Store the unit indoors.