TROUBLE SHOOTING PROCEDURES
Symptom
Bubbles in color cup
or bottle
Double Line / Not Spraying /
Skipping / Spattering
• Normal use of this product is likely to expose the
user to dust and/ or microscopic particles containing
chemicals known to the state of California to cause
cancer, birth defects or other reproductive harm.
Always wear appropriate safety equipment and
clothing when using this product. Study, understand
and follow all instructions provided with this product.
• Always wear ANSI approved goggles
when using this product
• Always use the correct accessories for
the job that you are performing.
• Always work in a clear, safe, well-lit,
organized and properly equipped area.
• NEVER begin repairs without ensuring that
vehicle is in secure position and will not
move during repair.
MABBR2
MODEL:
MABCR2
MABCR3
Problem
Loose needle packing screw
or damaged needle packing
Improper nozzle and
body connection
Broken or damaged nozzle
Clogged needle tip
Dirty air brush
Clogged nozzle tip
Bent needle
Broken or damaged nozzle
Loose needle lock screw
Improper air pressure
Paint too thick
Dried out air valve packing O-ring
Page 3
0.2mm nozzle size
with 2cc gravity cup
0.2mm nozzle size
with 8cc gravity cup
DUAL ACTION AIR BRUSH
0.3mm nozzle size
with 8cc gravity cup
Solution
Re-tighten #10 with a mini flat screwdriver;
replace #9 if it is worn out
Check #3 to reseat with the provided tool
Check #3 for replacement
See cleaning the needle
See cleaning the airbrush between colors
See cleaning the needle
Check #3 and clean with toothpick
Check #8 for replacement
Check #3 for replacement
Gently tighten #15 with fingers
See compressor instructions to
set appropriate pressure
See paint preparation
Lubricate #19A/C in air valve assembly
with Vaseline
Vaseline can be used for lubrication
DUAL ACTION