WARNING
!
The fan must be hung with at least 7' of clearance from
floor to blades (Figure 16).
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as "Acceptable for Fan Support of
22.7 kg. (50 lbs.) or less".
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable
for Fan Support of 22.7 kg. (50 lbs.) or less", and
use screws supplied with outlet box. Most outlet
boxes commonly used for support of light fixtures
are not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
4.1
Disconnect electrical power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to install
the Ceiling Fan on the Outlet Box (Figure 17).
AT LEAST
7'
Figure 16
Figure 17
12
CEILING
FLOOR
MAIN FUSE BOX
U.L. Model No.: CF755