Equipment Description - ims PRO PULSCOOL Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the installation of the welding equipment. During the installation, the
operator must ensure that the machine is disconnected from the mains. Connecting generators in serial or in parallel is forbidden.

EQUIPMENT DESCRIPTION

The GENCOOL cooling unit is a system designed to cool the water cooled torches connected to your GENIUS 400CC/CV welding machine.
The PULSCOOL cooling unit is a system designed to cool the water cooled torches connected to your PULSEMIG 400/500 G welding machine equip-
ped with a PULSFEED.
The TWINCOOL cooling unit is a system designed to cool the water cooled torches connected to your PULSEMIG 400/500 G welding machine
Equipped with two PULSFEED.
The WCU1KW cooling unit is a system designed to cool the water cooled torches connected to your TITAN 400 / TITANIUM / PULSEMIG 320C
welding machines.
These devices are controlled directly by the welding machine via two connection cables (FIG 1-6).
The PULSCOOL/TWINCOOL and the WCU1KW C are equipped:
- with a water level protection making sure the filling is at the minimum level for the good functioning of the cooling system but also for a good torch
cooling.
- with a water flow protection in order to protect the torch against a blockage at the level of the water circuit or a damage of the torch connection.
The PULSCOOL/TWINCOOL, the GENCOOL and the WCU1KW C are equipped with a thermal protection to prevent the torch for overheating abnor-
mally.
The recommended cooling system units are automatically detected by the machine.
GENCOOL / WCU 1kW C :
In the « Setup memory » menu of the wire feeder EXAFEED, the GENCOOL can be inhibited.
In the « Setup/CONFIG » menu of the TITAN 400, the WCU 1kW C can be inhibited.
PULSCOOL / TWINCOOL / WCU 1kW C :
PULSCOOL / WCU 1kW C :
On the HMI « Settings/Cooling unit » :
- AUTO: activation during welding and deactivation of the cooling unit 10 minutes after the end of welding.
- ON: the cooling unit is permanently controlled.
- OFF: the cooling unit is disabled.
- PURGE
: function dedicated to purging the cooling unit or filling the connection cables. The protections are then disabled.
DESCRIPTION OF THE EQUIPMENT (I)
1-
Coolant outlet
2-
Coolant inlet
3-
Tank level indicator
TROLLEY SET-UP (OPTION REF. 037328)
Warning! Do not connect the cooling unit whilst the welding machine is switched on.
GENCOOL
1
M6x12 (x4)
M6 (x4)
PULSCOOL / GENCOOL / WCU1KW C / TWINCOOL
(GENIUS)
4-
Fuse
5-
Filling cap
6-
Harnesses pre-cables
7-
Starter pipe
PULSCOOL/TWINCOOL
EN
(PULSEMIG 400/500G)
M6x12 (x3)
M6 (x3)
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

GencoolWcu1kw cTwincool

Tabla de contenido