DIODES TEST
The following method eliminates the need to disconnect
the diodes from the welder/generator wiring for checking
these.
1
Use a 12-volt battery and
an automotive lamp (type
5001) to test the diodes in
your equipment.
2
Connect the battery and
lamp as shown in the Fig.
aside
3
If the LEDs are working properly, the lamp shines when
the battery polarity is correct, and gives a dim light when
the polarity of the battery is reversed.
4
If there is no change in the brightness of the lamp when
the polarity is reversed, the diodes must be replaced.
TO TEST THE ROTOR AND THE STATOR WINDINGS
AND INDUCTORS, REFER TO AN AUTHORIZED
SERVICE CENTER.
MAINTENANCE
ATTENTION: Before any maintenance inspection,
disconnect all plugs from the panel receptacles and the
cable from the spark plug if the engine is of electric start.
Before each use, inspect the general conditions of the unit,
1
check that all parts are aligned and complete, check for
damaged cables or any other condition that may affect the
unit to operate safely. If any abnormal vibration or abnormal
noise is heard, turn the unit off immediately. Be sure to
fix that problem before further use. Do not use damaged
equipment. Periodically inspect all nuts and bolts (for being
in place and tight).
Store your equipment in a clean, dry place. For better
2
maintenance of the engine and any other problem, refer
to the engine owner's manual.
3
Once the motor has became cool remove surplus gasoline
and store it in a safe and approved container for this
purpose.
4
In the first 20 hours of use drain and replace engine oil,
after that the oil should be changed every 100 hours of
work.
ENGINE: Carburetor icing
During the winter months, unusual atmospheric conditions
could be developed that cause a condition of freezing in the
carburetor. If this happens, the engine could malfunction,
lose power and stop. For more information call the Service
Center.
Note: Refer to the manufacturer's engine manual for its
service and maintenance.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
All manuals and user guides at all-guides.com
TIPS FOR STARTING OF UNITS THAT
HAVE BEEN SITTING FOR AWHILE
If your unit has been out of service for an extended
period of time and is difficult to start, try doing some of
these easy steps before calling customer service.
1
Check the oil level.
2
Replace the old fuel.
3
Replace the spark plug.
4
Check the fuel pipelines. Make sure the fuel valve is
open.
Verify the integrity of all parts of the generator.
5
6
Clean the carburetor. (See engine manual for information
on service centers)
PERIODIC EXERCISING
If the unit is used infrequently, difficulties to start could
arise. To prevent these problems, run the unit for at
least 30 minutes every 15 days. In addition, if the unit is
going to be out of use for a long time , it is convenient
to remove the carburetor and fuel from the tank.
LONG TERM STORAGE
When the equipment is not being operated or is being
stored more than one month, follow the instructions
below before store the welder/generator:
1
Replace fill engine oil to upper level.
Remove the gasoline from the fuel tank, carburetor and
2
fuel line.
3
Pour one teaspoon of engine oil through the spark plug
hole, pull the retractable cord several times and place
the spark plug. Then pull the starter cord until you feel
that the piston career is in its compression position
and leave it in this position. This closes the intake and
exhaust valves to prevent the inside of the cylinder from
rusting.
4
Cover the unit and store in a clean, dry place with good
ventilation and away from sparks or flames.
Note: We recommend that you always use a stabilizer
to fuel. A fuel stabilizer will minimize the formation of
fuel gum deposits during storage. Fuel stabilizer can be
added to the gasoline in the tank of fuel or gasoline in a
storage container.