Select « DIAGNOSTIC MODE »
1
GYSFLASH 75-12hf displays « DIAG U = 13.5v » or the user defined
voltage selected by the user via the settings menu
Connect the clamps: red clamp on the "+" terminal , and black clamp
2
on the "-" terminal
3
Press « START »
4
During use, the instantaneous current consumption is displayed
5
To end the diagnostic mode, press « Start/Stop »
6
When the diagnostic has finished, turn the machine off
7
Unplug the power supply cable, then disconnect the clamps
BATTERY CHANGE MODE
The Gysflash 75-12 HF ensures a stabilised power supply while changing the battery in order to save
the memory settings.
1
Select « CHANGE BAT » mode
Connect:
A: The black "-" clamp to the vehicle chassis.
2
B: The "+" clamp to the end of the lug connected to the "+" battery terminal, in such a way
that the battery can be changed without disconnecting the clamp
3
Press « START/STOP », to launch the mode
4
During the process the instantaneous current consumption is displayed
Change the battery ensuring the polarity is correct
5
CAUTION: while exchanging the batteries, be careful not to disconnect the charger clamps as it
can cause the loss of electronic data
6
After changing, press « Start/Stop »
7
Unplug the power cable, then the clamps from the battery
SHOWROOM MODE
On display vehicles typically in car sales showrooms, the Gysflash 75-12 HF compensates the current
used (up to 75A) by high-energy consumers: heating, window regulator, dashboard, etc enabling
sustained display of the vehicle without fear of battery discharge. It delivers a stabilised voltage of:
- 13.5V (factory setting)
-
12V to 15V (adjustable by the user)
Showroom function
By using the « Showroom » function, the user is able to adjust the voltage to deliver during the
showroom phase to match manufacturer's recommendations. To adjust the voltage (default setting is
13.5V), check the settings menu page 15.
12