Simu CENTRIS S Manual Del Usario página 4

Ocultar thumbs Ver también para CENTRIS S:
Tabla de contenido

Publicidad

2
Crown dismantling
Motor with clamp fixing
1
2
1
3
Installation
3.1 - Tube preparation for motors with clamp fixing
45°
1 2
 &  : Power supply and
75°
declutching cables.
 &  : Motor fixation
3.2 - Installation of motors with clamp fixing (steps 1 to 7)
3
2
1
info
Fitting of Ø48 - Ø42 - Ø34 mm tube adapters : See instructions sheet delivered with the adapter set package.
2/4
Motor with fixing by clamping jaws
2
1
1
1
Ø 220 - 240
Ø 200
5 mm
6 mm
1
3
4
75°
2
3 4
Ø11 mm
Ø7 mm
180°
5
13 mm
6
7
4
6
5
7
3.3 - Tube preparation for motors with clamping jaws fixing
2
2
 &  : Power supply and
declutching cables.
 &  : Motor fixation
3.4 - Installation of motors with clamping jaws fixing (steps 1 to 5)
45°
45°
4
Passage of cables (all Centris range)
0
0
45 N.m
MAX.
Ø 200
7
Installation advice :
5 mm
- Remove any burr and sharp edges from the tube to avoid damage to cables.
10 N.m
±1
- Exit the disengagement cable in the motor alignment.
- The cables should not obstruct the rolling up of the curtain.
Ø 220 - 240
7
- Allow sufficient curvature radii (150 mm minimum) in order to prevent any blockage.
- Declutching handle assembly: See instructions sheet delivered with the declutching handle kit.
- Minimun length of the declutching cable sheath in case of shortening:
6 mm
24 N.m
±2
25°
1
3
4
115°
2
1 2
115°
Ø11 mm
2
1
2
4,5 m /
Unrestricted
*
**
25°
3 4
25°
Ø11 mm
5
5
6 mm
24 N.m
±2
4
3
3
8 mm
30 N.m
±3
4
5
r = 150 mm min.
r
r
3/4