Installation
Installation
Step 1: Rough-In
1. Rough in the wall opening.
NOTE: For units with side drain, a 1½" diameter hole in the side of the
wall opening is required for P-trap clearance.
2. Rough in the ½" NPT water supply.
3. Position the unit in the wall opening. Mount the unit to the wall
with four bolts (supplied by installer).
4. With the cabinet door open, connect the water supply using
the coupling nut and combination tailpiece (refer to page 4).
5. Open the water supply lines but do not activate the unit at
this time.
Step 2: Waste connections
1. FOR UNIT WITH TAILPIECE: Insert the bottom (non-flanged)
end of the tailpiece into the hole in the cabinet bottom. Slide
the tailpiece onto the drain pipe. Tighten the connection nut.
FOR UNIT WITH P-TRAP: Insert the P-trap into the cabinet
and slide the top end onto the drain pipe. Adjust for side or
rear drain according to your application.
2. Connect the 1¼" waste line (supplied by installer) to the
bottom of the tailpiece or P-trap.
3. Mount the safety sign to the wall with appropriate hardware
supplied by the installer.
1
"
"
7
7
16
8
(37mm)
(22mm)
Ø ¼" mtg. hole
29
"
5
32
(741mm)
to
mounting
holes
6"
(152mm)
Bradley Corporation • 215-1598 Rev. D; ECM 10-05-031
(qty. 4)
"ON"
position
15
(396mm)
22
"
3
8
(568mm)
4
"
11
16
(119mm)
16
"
13
32
(417mm)
"
19
32
½" NPT
supply
3"
(76mm)
Drain
2"
(51mm)
13
"
11
16
(366mm)
9/20/10
S19-292, S19-292PT
14½"
(368mm)
33¾"
(857mm)
25
"
5
8
(651mm)
17½"–29½"
(445mm–749mm)
to floor for ANSI
compliance
1¾"
18½"–20½"
(44mm)
(470mm–521mm) to
floor for "barrier free"
compliance
4
"
3
8
(111mm)
32¼"
(819mm)
4
"
3
8
(111mm)
1¾"
(44mm)
3