2.
How to use the machine
and surfing menu
2
10
9
8
4
13
Fig. 1:
Control panel
1. Data display
2. Direction LEDs for the unbalance point
3. Unbalance point (LED)
4. Button to set the DISTANCE of the circle
5. Button to set the DIAMETER of the circle
6. Button to set the WIDTH of the circle
7. SPLIT button
8. Button to select the unit of measurement of the width or the diam-
eter of the circle (MM/INCH)
9. Button for the control functions (SET)
10. Setting button for the balancing programme (MODE)
11. STOP button
12. START button
13. Setting buttons (-/+)
14. Optimisation button
15. OK button
We can divide the balancing machine menu in several
submenus:
$
Configuration of the use
$
Configuration of the board
$
Self-calibration
Auto-diagnosis
To roll down the options, keep SET pressed; to confirm
the entrance in the menu, press MM/INCH by 1,5 sec-
onds.
2.1
Configuration of the use
Press "SET" until the notice "TOL " is shown.
Display SX
Display DX
Descrizione
TOL
5
It indicates the threshold of the rec-
alibration of the balancing machine
RES
5
Visualization of the unbalance,
rounded off to 5g or real
UNB
GRA
Selection of the weight
(grams or once)
SND
ON
It indicates the acous-
tic sound (beep)
CAR
ON
It indicates the possibili-
ty to use the wheel protect-
ing carter for the launch
LAR
0.50
Visualization of the width:
0.50" or 0.25"
Robert Bosch GmbH
How to use the machine and surfi ng menu | WBE 5210 | 17
1
3
6
15
5
12
2.2
Configuration of the board
Press "SET" until the notice "TOL " is shown and then
press „MM/INCH".
Left Display Right Display Description
POT
OFF/ON
ALU
OFF/ON
9
PED
OFF/ON
14
PLR
OFF/ON
7
ROT
OFF/ON
11
2.3
Self-calibration
Press "SET" until the notice "CAL " is shown and then
press "MM/INCH.
Left Display Right Display Description
C-1
Left Display Right Display Description
D-1
0 or higher
Left Display Right Display Description
D-2
200
Left Display Right Display Description
L-1
L-2
Left Display Right Display Description
H-1
ex.: 14"
Left Display Right Display Description
C-2
C-3
C-4
C-5
2.4
Auto-diagnosis
Press "SET" until the notice "TST" is shown and then
"MM/INCH".
Left Display Right Display Description
Msr
ex.: 892
ex.: 1338
es.: 180
ex.: 810
ex.: 2
Turn on/off the inter-
nal automatic gauge
Turn on/off the gauge func-
tion called "aludata"
Turn on/off the function to read
the data through the pedal
Turn on/off the width gauge
Turn on/off the function to meas-
ure the eccenticy of the wheel
through the sonar (by request)
Memorization of the flange
zero group and shaft
Calibration of the sensor to meas-
ure the distance: position of rest
Calibration of the sensor to meas-
ure the distance: position at 20cm
Calibration of the sensor to meas-
ure the width. Position: all open
Calibration of the sensor to meas-
ure the width. Position: all closed
Calibration of the sensor to
measure the diameter
Setting up of the wheel size and
memorization of the unbalance
Setting up of the calibration weight
and launch with the weight inside
Launch with the weight outside
Adjustment of the angle
Press DISTANCE to roll down menu
1° shown value:
tension measured in left pick-up
2° shown value: tension meas-
ured in the right pick-u
3° shown value: phase an-
gle difference
4° value: Rounded off ra-
tio between the pick-ups
|
1 695 654 761