elobau 165 Serie Traducción Del Manual Original De Instrucciones página 4

Tabla de contenido

Publicidad

165...
- Where possible, the sensor and switching magnet should not be mounted on
ferromagnetic material. Changes to the switching distances are to be
expected. A non-magnetic spacer with a thickness of at least 8 mm must be
used.
Suitable washers for sensor and magnet are available from
elobau by order number 350005.
- The mounting distance between two sensor and switching magnet systems
must be at least 50 mm.
- Tightly fasten the safety sensor and the switching magnet to the safety
device.
- Only M4 flat head screws (e.g. M4 cylinder head screws ISO 4762) may be
used for mounting the sensor and switching magnet. Max. tightening torque
2 Nm. Screws made from non-ferromagnetic material (e.g. brass) must be
used.
For securing the locking screws against easy disassemble, Allen-
type locks made of PA are available from elobau:
Order number 351040 for cylinder head screws DIN EN ISO
4762/M4 (previously DIN 912)
- The safety sensor may only be mounted on an even surface as failure to do
so may lead to tension which could damage the sensor or alter the switching
distances.
- The connection cable of the sensor must be protected against mechanical
damage.
- During the assembly process, the requirements according to DIN EN 1088 /
ISO 14119 standards should be taken into consideration.
10 Adjustment
- Always test the correct functionality with one of the approved safety control
units.
- The specified switching distances (see Technical specifications) only apply
for mounting on non-ferromagnetic material if the safety sensor and
switching magnet are mounted in parallel and facing each other. Other
layouts may lead to deviating switching distances.
11 Electrical connection
- The electrical connection is only permitted in a voltage-free state.
- Connect the safety sensor according to the specified wire colours or pin
assignment (see Technical specifications).
For sensors with male connectors, suitable cable sets and
connectors for assembly are directly available from elobau.
- Please ensure that the voltage does not fall below the required minimum
input voltage of the downstream safety processing unit. For that reason
observe the voltage drop at the sensor (series resistor) and in the connection
cable.
- The voltage drop for the internal LED circuit is to be considered additionally
for LED sensors (see technical specifications).
The luminance of the LEDs can reduce in relation to the number
of opened protective doors where multiple LED sensors are used.
- For series connection of the safety sensors (verify approval in advance) their
respective NO paths must be connected in series and the respective NC
paths must be connected in parallel.
12 Commissioning
When commissioning, the following points must be ensured in advance:
- the safety sensor and switching magnet are positioned correctly and
mounted in a fixed position
- the supply line is intact
- there are no iron filings on the sensor and switching magnet
The safety sensor and the connected control unit must then be tested for
correct functionality.
Art.-Nr./Art. No./Réf./N° art/N° art.: 900551
13 Maintenance
If the safety sensor is mounted and used correctly, no maintenance measures
are be necessary.
We recommend a visual and functional inspection carried out at regular
intervals:
- check that the sensor and switching magnet are firmly seated
- inspect the connection cable for damage
14 Dismantling
The safety sensor may only be dismantled in a voltage-free state.
15 Disposal
Dispose of packaging and used parts in accordance with the regulations of the
country in which the device is installed.
16 Information on the manufacturing date
Capteur de sécurité 165...
Traduction de la notice d'utilisation d'origine
1
Sont décrites les variantes des types de base suivants:
165260; 165262; 165262AFA; 165V62; 165V62A0D; 165270; 165270A0D;
165270A0E; 165270AA;
Les fiches techniques supplémentaires des détecteurs sur mesure peuvent
être obtenues sur demande auprès d'elobau. Pour les types sur mesure, les
données de la fiche technique sont valables si ces dernières sont différentes
de celles mentionnées dans la notice d'utilisation.
Les instructions de service doivent être mises à disposition de la personne qui
installe le détecteur de sécurité.
Les instructions de service doivent être conservées dans un état lisible et
doivent être accessibles.
Signification des symboles utilisés:
2
Associés aux unités de contrôle de sécurité elobau et aux commandes de
sécurité comparables, les détecteurs de sécurité servent exclusivement à
surveiller des dispositifs de sécurité de séparation mobiles.
Le concept global du système de commande dans lequel est intégré le
détecteur de sécurité doit être conforme à la norme DIN EN ISO 13849-2.
Version/Version/Version/Versione/Versión: 2.0
Damaged or faulty devices must be exchanged with original
replacement parts!
The manufacturing date can be seen on the sensor casing in the
form of "calendar week/year":
e.g. "19/11" = calendar week 19 / year 2011
À propos de cette notice d'utilisation
 Attention
En cas de non-respect des instructions, des pannes ou des
dysfonctionnements risquent de se produire.
Le non-respect des instructions peut entraîner des blessures
et/ou des dommages matériels.
 Information
Signale des accessoires disponibles et des informations
complémentaires utiles.
Utilisation conforme
Datum/Date/Date/Data/Fecha: 12.02.2013
F
4/16

Publicidad

Tabla de contenido
loading