Kohler K-18829 Guía De Instalación Y Cuidado página 20

Ocultar thumbs Ver también para K-18829:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
Cause
C. Poorly adjusted
2.
Fill valve does
A. Water level is
not shut off.
B. Flush valve
C. Flush valve is
3.
Leaks from
A. Gaskets are not
behind the bowl.
1246750-2-C
Recommended Action
C. Verify that the
rod.
threaded rods behind
the faceplate make
contact with the flush
buttons. If they do not
make contact, thread
the rods out to the
correct length, and
tighten the nuts to
lock the rods in place.
A. Lower the tank water
too high.
level to the marked
waterline. Turn the
white knob on the fill
valve
counterclockwise.
B. Replace the flush
gasket or flush
valve gasket or flush
valve are
valve as necessary.
damaged.
C. Check the flush valve
sticking open.
and actuating
mechanism for free
movement. Push
button actuators
should raise the levers
and then spring back
without force. Replace
components as
necessary.
A. Remove the bowl and
positioned
inspect all the gaskets.
correctly.
Reposition the gaskets
if needed. Lubricate
the gaskets so they
slide over the mating
part they seal.
Reinstall the bowl,
making sure the
gaskets stay in the
correct position.
20
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido