Airfusion Radar Installation Instructions
D - LIGHT CONTROL BUTTON: (Light kit sold separately)
Press the button to turn the light ON/OFF.
Press and hold the button to access the light dimming function.
E – D / ON SWITCH
This
switch marked
D/ON controls the dimming function of the lights. If using
non-dimmable bulbs, use a ballpoint pen or small screwdriver to set the switch
to "D" to disable the dimming function. If using dimmable halogen bulbs, set the
switch to "ON" to enable the dimming function. Fig. 13
THE RECEIVER PROVIDES THE FOLLOWING LEVEL OF PROTECTION:
Lock position: the receiver has a built in safety feature to protect against obstruction during operation.
The motor will be locked from operation and will disconnect from power after 30 seconds of interruption.
Please remove obstacles before re-starting. To reset, simply turn off the power supply to the fan motor
and re-start.
Over 80W protection: when the receiver detects power consumption which is greater than 80W, the
receiver power will be stopped and operation will immediately discontinue. Turn the receiver power on
after 5 seconds to restart the fan.
REPAIRING THE FAN RECEIVER & REMOTE PAIRING
Should the remote and receiver lose control after installation or during use, the pairing of the remote
and the receiver must be repaired. Below are the operating symptoms and method to repair the pairing
of the DC ceiling fan remote and receiver.
Issues:
Loss of control - Fan is only running at high speed after installation
Loss of control - No reverse function after installation
Loss of control - Remote cannot communicate with receiver
Solution:
A. Switch OFF the main power to the ceiling fan for 30 seconds.
B. Press and hold the "SET" button on remote for 6 seconds within 60 seconds of switching the power ON
to the receiver of the ceiling fan.
While pairing the DC fan remote and receiver is in process, the fan will automatically start to rotate in the
counterclockwise direction and on the highest RPM for 3 minutes. When counterclockwise rotation has
finished, the fan will automatically reverse to clockwise direction again to the highest RPM for 3 minutes.
Fan will turn off when the pairing process has finished. During the pairing process, the remote is non-
functional.
C. Turn ON and change the speed of the ceiling fan via the transmitter to check the operation and successful
pairing.