Time menu setup
Time menus allow setting a function duration. When you enter
into a time menu, the current setup value will be viewed; the
display mode depends on the current value:
• Times being lower than one minute will be viewed as follows:
each time you press UP key, current time value increases of
half a second; vice versa, each time you press the DOWN
key, current time value decreases of half a second.
• Times between 1 and 10 minutes will be viewed as follows:
each time you press UP key, current time value increases of
5 seconds; vice versa, each time you press the DOWN key,
current time value decreases of 5 seconds.
• Times being more than 10 minutes will be viewed as follows:
each time you press UP key, current time value increases of
half a minute; vice versa, each time you press the DOWN
key, current time value decreases of half a minute.
By holding down the UP key, you can quickly increase the time
value, up to reach the max. value allowed for this item. Vice
versa, by holding down the DOWN key, you can quickly decrease
the time value down to reach 0.0".
In some circumstances, setting the value to 0 means that the
relevant function is disabled, in this case, 'no' will appear
instead of 0.0".
By pressing on MENU you will confirm the displayed value and
you will return to the configuration menu.
Value menu setup
Value menus are similar to time menus; however, the setup
value can be any number.
By holding down UP or DOWN keys, the value will increase or
decrease slowly.

QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control
unit and set it at work immediately. We recommend following
these instructions, in order to check quickly the correct
operation of control unit, motor and accessories, and then
changing the configuration in case of any non-satisfactory
parameter. Please refer to the paragraph "Control unit
configuration" for the item position inside the menu, as well as
for the available options for each item.
1. Call up a default configuration (see paragraph "LOADING
OF DEFAULT PARAMETERS").
2. Set items StoP, Foto, CoSt and FC.En according
to the safety devices installed on the gate.
3. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store
set up parameters.
Self-learning procedure:
• In case the end of stroke or the obstacle sensor has been
enabled, the gate will be activated in closing direction until
the stop end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor
have been enabled, be sure that the gate is completely
closed when the procedure is started up.
• The gate will be activated in opening direction until the stop
end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command when the gate reaches its
max. opening position.
• The gate will be activated in closing direction until the stop
end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command must be sent when the gate
reaches its fully closed position.
IMPORTANT: at the end of the learning cycle, the level of
current absorption peak measured during the cycle with the
exception of the peak stages, appears on the display for a few
seconds.
The installer can work on the basis of this of information to
establish the threshold of the obstacle sensor, bearing in mind
that it is essential to leave a small margin to prevent even a
minimum amount of friction or binding blocking the gate.

CONTROL UNIT CONFIGURATION

This paragraph concerns the step-by-step procedure to set all
operation parameters of 900CT-380 control unit. You can
either follow all procedure steps and perform a complete
control unit configuration or select and adjust interesting items
only. As for both cases, you will have to perform the right exit
procedure through item FinE, in order to activate your new
configuration.
900CT-380 control unit provides for a self-learning procedure of
working times; therefore, we recommend that you set up a
standard configuration first (see previous paragraph), then you
carry out the self-learning and finally you change any
unsatisfactory items.
25