Electric Connections Table - Key Automation 900CT-380 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

A1
Antenna shield
A2
Antenna
Opening control for the connection of control
P1
devices with N.O. contact
Opening controls for pedestrian access for the
P2
connection of control devices with N.O. contact
P3
Stop command. N.C. contact
P4
Common (-)
P5
Photocells type 1. N.C. contact
P6
Photocells type 2. N.C. contact
P7
Safety ribbons type 1 (fixed). N.C. contact
P8
Safety ribbons type 2 (mobile). N.C. contact
P9
Common (-)
P10
Opening end of stroke. N.C. contact
P11
Closing end of stroke. N.C. contact
Power output 24 VAC for photocells and other
P12
accessories
P13
Photocell TX power supply for functional test
P14
Common (-)
TABELLA COLLEGAMENTI ELETTRICI
36
W1 - W2 -
Motor (see paragraph POWER SUPPLY AND
W3
MOTORS)
Clamps to connect the motor's earth system to
W4 - W5
the plant's earth system
B1 - B2
Flashing light 230VAC 40W
1L1 - 3L2 -
Power supply (see paragraph POWER SUPPLY AND
5L3
MOTORS)
F1
400mA
F2 - F4
2A
F3
2A (500V)
ADI
Optional modules connector
MAINS
It shows that the control unit is power supplied
It shows that there is an overload on accessories
OVERLOAD
power supply
FCC
It shows the opening end of stroke activation
FCA
It shows the closing end of stroke activation
OP
Opening in progress
PA
Pause (gate opened)
CL
Closing in progress

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

900ct-381

Tabla de contenido