Troubleshooting - AquaPRO 33011-6 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

Problem
The pump does not start or run.
The pump operates but pumps
little or no water.
The pump starts and stops too
often.
The pump will not shut off.
Possible Cause
1.
The fuse is blown.
2.
The breaker is tripped.
3.
The plug is disconnected.
4.
The plug is corroded.
5.
There is thermal overload.
6.
The switch failed.
7.
The motor failed.
1.
The screen is blocked.
2.
Debris is caught in the impeller or
discharge.
3.
The impeller is loose on the shaft
or the impeller is broken.
1.
There is a backflow of water from
the piping or the check valve is
leaking.
2.
The float switch is stuck.
1.
The switch is tangled.
2.
The float switch is faulty.
3.
The float is obstructed.
7
Corrective Action
1.
Replace the fuse.
2.
Reset the breaker.
3.
Secure the plug.
4.
Clean the plug prongs.
5.
Unplug for 30 minutes and
then plug in again.
6.
Replace the switch.
7.
Replace the pump.
1.
Clean the screen.
2.
Remove the debris.
3.
Reassemble the impeller or
replace the impeller.
1.
Install a check valve or
replace the check valve.
2.
Clean the float switch to
make sure the float moves
up and down freely.
1.
Reposition the pump and
make sure the switch
moves freely.
2.
Replace the switch.
3.
Remove the obstruction.

Publicidad

Tabla de contenido
loading

Tabla de contenido