MATERIALS REQUIRED (NOT INCLUDED)

NOTE: Parts shown below not to scale.
Threaded Adapter
(Pipe to Pump)
1-1/4" or 1-1/2"
check valve
SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Sump basin
NOTE: Do not reduce size of discharge pipe or hose below 1-1/4 in. diameter. If discharge is too small, pump will
overheat and fail prematurely. This pump is designed for use in a residential sump only. Only pump water with this
pump.
INSTALLATION
1. Install the pump in sump pit with minimum diameter of 10 in. (254 mm) for models equipped with vertical
switches and 14 in. (356 mm) for tethered float switch models. The sump depth should be 14 in. (356 mm) for
vertically switched models and 18 in. (457 mm) for tethered models. Construct the sump pit of tile, concrete,
steel or plastic. Check local codes for approved materials and for proper installation.
2. Install the pump in a pit so that the switch operating mechanism has maximum possible clearance.
1-1/4'' or 1-1/2''
ABS or PVC Pipe
ABS or PVC Cement
(to match the pipe)
115V, 60 HZ., 15 Amp Circuit
32 to 77°F (0- 25°C)
1-1/2 in. FNPT or 1-1/4 in. FNPT (with adaptor)
Min. 14 in. (356 mm) diameter, 18 in. (457 mm) depth for tethered switch
Min. 10 in. (254 mm) diameter, 14 in. (356 mm) depth for vertical switch