OPERATION
Controls (Fig.1)
The hood is operated using the (5) push buttons located on the front edge of the hood. The
Light On/Off buttons turn the lights on and off.
The Blower Off / - button decreases the blower speed each time pressed. Depress and
hold the button for 2 seconds to turn the blower off.
The Blower On /+ button turns the blower on and increases the blower speed each time
pressed. There are four different speed settings: Low, Medium-Low, Medium-High and High.
The Blower LED Indicators illuminate to indicate the selected blower speed.
The Delay button activates the delay-off feature. When the blower in on and the button is
pushed, the blower will continue to operate at the current speed setting for 10-minutes
before automatically turning itself off. The LED (on the right) flashes during operation.
The LED (on the right) is also used as a filter clean reminder. It will flash after 30 hours of
operation - indicating the need to clean the filters.
The Filter Clean Reset button is used to reset the 30-hour filter timer. After filters are
cleaned or replaced, press button once to reset the filter clean alarm.
Auto Shut-Off Feature
If the blower and/or the lights are on continuously for 10 hours without any user interaction
with the controls, the hood will automatically shut off. Press any control button to re-activate
the hood.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a device that
will turn on or speed up the blower if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF.
When this occurs, it is impossible to turn the blower OFF with its switch. If you must
stop the blower, do it from the main electrical panel.
- 6 -