SecTION 2
Type of Gas
Pressure
Flow
Purity Required
Recommended Liquid Cylinder Service Regulators
Recommended cylinder 2-Stage Regulators
Recommended Heavy-Duty Hi-Flow
Station or Pipeline Regulators
Type
Pressure
Flow
Purity Required
Type
Pressure
Flow
Purity Required
PT-26 Technical Specifications (Plasma gas)
PT-26 Technical Specifications (Starting gas/cutting gas)
PT-26 Technical Specifications (Shield gas)
16 .5"
(419mm)
figure 1 - PT-26 In-line Torch Dimensions
figure 2 - PT-26 Manual Torch Dimensions
13
N
, Air, AR-H
, N
-H
2
2
2
2
100 psig (6 .9 bar)
240 cfh (6 .8 M
/h)
3
O
- 99 .5% min ., N
-99 .995% min ., Air - clean and dry
2
2
Inert Gas
R-76-150-580LC
Argon-Hydrogen
R-77-75-350
Nitrogen
R-77-75-580
Industrial Air
R-77-150-590
Nitrogen
R-76-75-034
N
, Air (for Ar-H
Cut Gas Use N
2
2
100 psig (6 .9 bar
200 cfh (5 .66M
/h) @ 60 psig (4 .1 bar)
3
N
- 99% min ., Air - clean and dry
2
N
or Air
2
100 psig (6 .9 bar) maximum
200 cfh (5 .66 M
/h) @ 85 psig (5 .86 bar)
3
Nitrogen - 99% minimum, Air - clean and dry
DeScRIPTION
19977
998341
998343
998348
19155
or Ar-H
)
2
2
2"
(50 .8)