Note
Electromagnetic compatibility (EMC)
You can use this device in industrial environments, households and small businesses.
For metal housings there is an increased electromagnetic compatibility compared to high-frequency radiation. This
protection can be increased by grounding the housing, see Electrical connection (Page 17).
Note
Improvement of interference immunity
Lay signal cables separate from cables with voltages > 60 V.
Use cables with twisted wires.
Keep device and cables in distance to strong electromagnetic fields.
Take account of the conditions for communication specified in the Technical data (Page 23).
HART: Use shielded cables to guarantee the full specification according to HART.
5.1.1
For SITRANS TSinsert/TS200/TS500
NOTICE
Ambient temperature too high
Damage to cable sheath.
At an ambient temperature ≥ 60 °C (140 °F), use heat-resistant cables suitable for an ambient temperature at least
20 °C (36 °F) higher.
5.1.2
For SITRANS TS100/TS200
WARNING
Use of plug connectors in explosive dust atmosphere
Danger of explosion.
Temperature sensors of the SITRANS TS100 and SITRANS TS200 series must not be used together with plug connectors
in atmospheres with combustible dust.
Do not use plug connectors in areas with combustible dust.
5.1.3
For SITRANS TS500
NOTICE
Condensation in the device
Damage to device through formation of condensation if the temperature difference between transportation or storage and
the mounting location exceeds 20 °C (36 °F).
Before taking the device into operation let the device adapt for several hours in the new environment.
5.2

Electrical connection

Procedure
Note
Connection sequence
Install the temperature transmitter before connecting the temperature sensor electrically.
1. Release the fixing screws on the enclosure cover and remove the enclosure cover.
SITRANS TSinsert/TS100/TS200/TS300/TS500 (7MC71.. 7MC72.. 7MC80.. 7MC75.. 7MC65.. 7MC55..)
A5E03920348-AB, 03/2016