2. Insert the connecting cable through the cable gland.
3. Connect the wires to the relevant connecting terminals. Observe the terminal assignment.
–
Electrical connection of resistance thermometers (Page 18)
–
Electrical connection of thermocouples (Page 18)
–
Electrical connection of connectors (Page 19)
See also
Electrical data (Page 27)
5.3
Electrical connection of resistance thermometers
2-wire connection
3-wire connection
4-wire connection
Abbreviation of color: RD = red; WH = white; YE = yellow; BK = black
5.4
Electrical connection of thermocouples
1 thermocouple
Thermocouples
Type
J
18
1 x RTD
SITRANS TSinsert/TS100/TS200/TS300/TS500 (7MC71.. 7MC72.. 7MC80.. 7MC75.. 7MC65.. 7MC55..)
Cable colors
+
Black
2 x RTD
2-wire connection
3-wire connection
4-wire connection
2 thermocouples
-
White
A5E03920348-AB, 03/2016