3.5 CONFIG MENU
To access to configuration menu switch button 7 (Setup button) on position
All parameters are editable by pressing
button 7 (Setup button).
The table below details all parameters available in this menu:
Parameter
Reset memory and go back to default factory values for
Reset factory
Wire speed uses for manual wire command. Value is
Manual wire speed
Wire speed uses before arc ignition. This is a percent of
Low wire speed
Avoid wire stick at the end of welding. Value is displayed
Burnback time
Post display time
measurements are displayed when welding is stopped.
Fan control
Harness length (for
Setup of length of harness. Put this parameter on the
separated version
only)
Cooler control (for
water version only)
3.6 ESP (EASY SYNERGIC PROGRAM) USE
The equipment has a help with settings module: after the metal sheet
thickness is selected, the power source gives the position of choke,
commutators and set recommended wirespeed.
CONDITIONS OF USE:
ESP mode is set to be used in standard welding conditions:
● Flat welding
● Flat welding in a corner
● Use of solid wire
TABLE OF GAS:
Gas selector position
FeArCO₂
FeCO₂
CrNi
AlMg
and
buttons. All changes are saved when exit menu. Exit the menu by changing position of
Description
all previous parameters.
displayed in meter per minute.
the welding wire speed set.
in millisecond.
Allow to set a time during which the welding
Value is displayed in second.
Control the operating mode of the fan.
good position in order to have better result of wire
regulation. Value is displayed in meter.
Control the operating mode of the cooler.
Gas used for ESP point
ARCAL FORCE
ARCAL MAG
ARCAL CHROME
ARCAL PRIME
and do long press on button
Text on
screen
rES
ASP
1.0 m/min
LSP
bur
Pod
FAn
HAr
Coo
TABLE OF WIRE:
Metal selector
Wire designation
position
FeArCO₂
Steel solid wire
FeCO₂
Stainless steel solid
CrNi
AlMg
Aluminium solid wire
.
Adjustment values
Min
Max
No
Yes
12.0 m/min
7.5 m/min
10 %
100 %
10 ms
500 ms
0.1 s
10 s
Auto
On
5 m
10 m
OFF
On
Wire used for
ESP point
Filcord
Nertalic 70
Filinox
wire
Filinox 308 Lsi
Filalu AIMg₅
EN
Default
No
25 %
70 ms
3 s
Auto
5 m
Auto
13