EN
Before doing any work on the machine, discon-
nect the electricity and water supplies and dis-
charge the pressure. Proceed systematically to
identify faults following the chart below; if you
are still unable to eliminate the problem, call in
the Authorized After-Sales Service.
Fault
Cause
Repair
Fault
Cause
Repair
Fault
Cause
Repair
26
When the main switch is
turned on the machine
does not start
• Plug not properly connect-
ed.
• Connection panel fuses
are burnt out.
• Carefully check the plug
and the electric cable.
• Check them and replace
them.
The motor hums but does
not start
• A phase is missing (in
three phase models).
• Lows voltage.
• High pressure pump is
blocked.
• Contact an authorised
service centre.
• Contact an authorised
service centre.
• Contact an authorised
service centre.
The motor stops suddenly
or after a while
• The
motor-protecting
switch is on because of in-
sufficient mains voltage.
• Check the value of the
mains voltage.
• Contact an authorised
service centre.
Fault
When the lance is turned
on pressure values de-
crease and increase
Cause
• The
clogged or deformed.
• Either boiler coil or lance
are clogged with lime-
stone.
Repair
• Either clean it or replace it.
• Descaling.
Fault
To much vibrations at the
delivery
Cause
• The valve are worn out or
dirty.
Repair
• Check and/or replace.
Fault
The pump does not reach
the fixed pressures
Cause
• The pump sucks air.
• The valves are worn out.
• The setting valve area is
worn out.
• The nozzle is unsuitable or
worn out.
• The seals are worn out.
Repair
• Check the suction pipes.
• Check and/or replace.
• Contact an authorised
service centre.
• Contact an authorised
service centre.
Fault
Irregular pressure fluctua-
tions
Cause
• The suction and/or deliv-
ery valves are worn out.
• Presence of foreign mat-
ters in the valves, which
generate bad functioning.
• Air suction.
• The seals are worn out.
nozzle
is
either