10. Technical data

10.1 Operating conditions

System pressure
Max. 87 psi (6 bar / 0.60 MPa)
Max. 26.25 ft (8 m), including inlet-pipe
Suction lift
pressure loss at a liquid temperature
of 68 °F (20 °C)
Max.
Liquid temperature
104 °F (40 °C) (S1 mode*) /
140 °F (60 °C) (S3 mode**)
Max.
Ambient
104 °F (40 °C) (S1 mode*) /
temperature
131 °F (55 °C) (S3 mode**)
Relative humidity
Max. 98 %
Enclosure class
IP44
Insulation class
F
1 x 115 V, 60 Hz
Supply voltage
1 x 230 V, 60 Hz
Start/stop
Max. 20 per hour
frequency
Max. sound pressure level of the pump:
JP PS 13 03 137: 68 [dB(A)]
Sound pressure
JP PS 18 05 154: 70 [dB(A)]
level
JP PS 18 07 177: 74 [dB(A)]
JP PS 16 10 187: 81 [dB(A)]
* S1 mode: The pump runs continuous operation.
** S3 mode: The pump's overheating protection ensures the pump runs intermittent
operation when the air temperature is too high to cool the motor efficiently.
Related information
4.1.3 Ambient temperature during operation
4.2.2.1 Maximum system pressure

10.2 Head and flow rate

JP PS 13 03 137: 137 ft (42 m)
JP PS 18 05 154: 154 ft (47 m)
Max. head
JP PS 18 07 177: 177 ft (54 m)
JP PS 22 10 157: 180.5 ft (55 m)
JP PS 13 03 137: 13.2 gpm (3 m
JP PS 18 05 154: 17.6 gpm (4 m
Max. flow rate
JP PS 18 07 177: 17.6 gpm (4 m
JP PS 16 10 187: 22.0 gpm (5 m

10.3 Inlet pressure

Model
Max. inlet pressure
JP PS 13 03 137
21.75 psi (1.5 bar / 0.15 MPa)
JP PS 18 05 154
14.50 psi (1.0 bar / 0.10 MPa)
JP PS 18 07 177
7.25 psi (0.5 bar / 0.05 MPa)
JP PS 16 10 187
14.50 psi (1.0 bar / 0.10 MPa)
Related information
4.2.2.1 Maximum system pressure
22

10.4 Miscellaneous data

Cut-in pressure
Min./max. storage
temperature

11. Disposing of the product

1.
Use the public or private waste collection service.
2.
If this is not possible, contact the nearest Grundfos company or
service workshop. See also end-of-life information at
www.grundfos.com/product-recycling.
3.
Consider recycling scrap metal to reduce waste and to help to
limit new mining.
3
/h)
3
/h)
3
/h)
3
/h)
Preset cut-in pressure (start pressure):
JP PS: 30-50 psi
-4/+158 °F (-20/+70 °C)