AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩµA jack
into COM jack
V
setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the "SELECT" button
to toggle between AC and DC modes. The AC or DC icon on
12
the LCD indicates which mode is selected. Note "AC" or "DC" on
the display.
Black lead
Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the most
appropriate range.
NOTE: If "–" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.