Descargar Imprimir esta página

Kenmore 146. 34436410 Manual De Uso Y Cuidado página 30

Parrilla a gas de propane liquido

Publicidad

Idiomas disponibles

Idiomas disponibles

EMERGENCIES:
If a gas leak cannot
be stopped,
or a fire occurs due to gas leakage,
call the fire department.
Gas leaking from
cracked/cut/burned
hose
Gas leaking from LP
cylinder
Gas leaking from LP
cylinder valve
Gas leaking between LF
cylinder and regulator
connection
Fire coming through
control panel
Grease fire or
continuous excessive
flames above cooking
surface
Troubleshooting
• Damaged hose
• Mechanical
failure due to rusting or
mishandling
• Failure of cylinder valve from
mishandling or mechanical failure
• Improper installation, connection not
tight, failure of rubber seal
• Fire in burner tube section of burner
due to blockage
• Too much grease buildup in burner
area
• Turn off gas at LP cylinder or at source on natural gas systems
If the hose is cracked or cut but not burned, simply replace
valve / hose / regulator
If the hose is burned, the cause could
be other than a faulty valve/hose/regulator
Discontinue use of
grill until a plumber or gas technician has investigated and
corrected the problem
• Replace LPcylinder
• Turn off LPcylinder valve Return LP cylinder to gas supplier
• Turn off LP cylinder valve Remove regulator from cylinder and
visually inspect rubber seat for damage
See LPCylinder Leak
Test and Connecting Regulator to the LPCylinder
• Turn off control knobs and LPcylinder valve Leave Iid open to
allow flames to die down After fire is out and grill is cold,
remove burner and inspect for spider nests or rust See Spider
Alert and Cleaning the Burner Assembly sections of this Use &
Care Guide
• Turn off control knobs and LPcylinder valve Leave Iid open to
allow flames to die down After cooling, clean food particles
and excess grease from inside firebox area, grease tray, and
other surfaces
Burner(s) wilI not light
using igniter
(See Electronic
Ignition
Troubleshooting
also)
Continued on next
page
GAS ISSUES:
• Trying to light wrong burner.
Burner not
engaged
with
control
valve
• Obstruction in burner
• No gas ftow
• Vapor
Iock at coupling
nut to LP
cylinder
• Coupling nut and LP cylinder valve not
fully connected
• Electrode cracked or broken; "sparks
at crack
• Electrode tip not in proper position
• Wire and/or electrode
covered with
cooking residue
• Wires are loose or disconnected
• Wires are shorting (sparking)
between igniter and electrode
• Dead battery
• See instructions on control panel and in Use and Care section
• Make sure valves are positioned inside of burner tubes
• Ensure burner tubes are not obstructed with spider webs or
other matter See cleaning section of Use and Care
• Make sure LPcylinder is not empty If LPcylinder is not empty,
refer to "Sudden drop in gas flow"
• Turn off knobs and disconnect coupling nut from LP cylinder
Reconnect and retry
• Turn the coupling nut approximately
one half to threequarters
additional turn until solid stop Tighten by hand onty
do not use
tools
• Replace electrode (s)
Main Burners:
• Tip of electrode should be pointing toward gas port opening
on burner The distance should be 1/8" to 1/4" Adjust if
necessary
Sideburner
• Tip of electrode should be pointing toward gas port opening
on burner the distance should be 1/8" to 3/16" Adjust if
necessary
• Clean wire and/or electrode with rubbing alcohol and clean
swab.
• Reconnect wires or replace electrode/wire
assembly
• Replace igniter wire/electrode
assembly
• Replace with a new AAA size alkaline battery
30 ° 34436-00500120