Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
8
COOLANT
Make sure that the cooling unit is turned off before disconnecting the liquid inlet and/or outlet hoses of the torch. The coolant is
harmful and can irritate the eyes and skin. Hot liquid may cause burns.
Risk of burns due to hot liquid Never drain the cooling unit immediately after use. The liquid contained inside is boiling, wait
until it cools down before draining.
max
min
TWINCOOL CONNECTION
NEOFEED 2
NEOCOOL / EXACOOL / WCU1KW C / TWINCOOL
The operator must fill the tank up to its maximum indicated on the front of the cooling unit
but never under the minimum line or a warning message will be displayed on the screen.
It is essential to use a specific welding coolant with low electrical conductivity, being anticor-
rosive and anti-freezing (ref. 052246).
The use of any other coolant (in particular the automotive standard coolant), can lead, by
electrolysis effect, to the accumulation of solid deposits in the cooling system, thus damaging
it and also blocking the circuit.
This recommended maximum level is essential to optimise the duty cycles of the cooled torch.
Any damage to the machine due to the use of a different coolant than the recommended type
will not be covered by the guarantee.
feeder number is indicated on the interface.
Example: Wire feeder no.1
NEOFEED 1
M6x16 (x4)

M6 (x4)

M6x16 (x4)
M6 (x4)
FILLING
Follow the connection diagram shown to avoid damaging the lamp. The wire
EN
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

ExacoolWcu1kw cTwincool

Tabla de contenido