6.1.1 Maintenance of the smoke system

To be performed at least once a year, or every 40
tons of burned pellets.
If there are horizontal sections, it is necessary
to check and remove any ash and soot deposits
before they block the passage of the fumes.
In the event of failure or inadequate cleaning, the
stove may have functional problems such as:
-
bad combustion
-
glass blackening
-
burn pot blockage with build-up of ash and

6.1.2 Stove maintenance

It must be carried out at least once a year, or
each time the stove indicates that maintenance is
required.
During the maintenance operation, the technician
must:
-
clean the fume transit area thoroughly and
completely;
-
check the condition and tightness of all the
seals;
-
check the condition of all internal components
and make sure they are clean;
-
make sure the smoke outlet connection is
sealed and clean;
-
remove any deposits of pellet residues in the
tank;
-
make sure that the stove is working properly;
-
Reset any warnings or alarms (the manually
rearmed thermostats are on the rear of the
stove near the power cable)
-
For easy access to the fan (A), just remove the
lid (D), the cap (B) and relevant gasket, then
turn the two screws (C) (Fig. 6.1.2).
6.1.3
It is recommended to carry out the cleaning
evacuation compartment needs to be cleaned of
any residue.
Remove the lid (D) (Fig. 6.1.2).
Remove the screws securing the left side (Fig.
6.1.3a).
and cap (C) (Fig. 6.1.3b).
Finish cleaning by vacuuming any ash residue in
the cap and fan using a suitable ash vacuum.
gas evacuation duct and the side panel.