Information for the measurement
If OL appears in the display, the current measured is greater than the measuring range set,
change to the next higher range.
Measuring range
60 A
600 A
Integration time: 100 ms
Measuring range: ~30 to 600 A
Max. input current: 600 A
Frequency range: 40 to 400 Hz

DC measurement

Measuring range
60 A
600 A
Max input: 600A DC

DC voltage (automatic range selection)

Measuring range
600 mV
6 V
60 V
600 V
Input impedance: 10 M
Maximum input voltage. 600V DC or 600V AC RMS.

AC voltage (automatic range selection)

Measuring range
600 mV
6 V
60 V
600 V
Input impedance: 10 M
Frequency response: 40-400 Hz
Maximum input voltage. 600 V DC or 600 V AC RMS.
®
Testboy
TV 216N
Resolution
0.01 A
0.1 A
Resolution
0.01 A
0.1 A
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
Tolerance
Only regard < 60 A as a
reference value
>60 A ±10.0 % +60 digit
Tolerance
±3.0 % +10 digit
Tolerance
± (0.8 % + 3 digits)
± (1.0 % + 5 digits)
Tolerance
± (1.5 % + 10 digits)
± (1.2 % + 5 digits)
± (1.5 % + 10 digits)