Information for the measurement
Off-load voltage: 0.4 V
Overload protection: 250 V DC or 250 V AC RMS

Acoustic continuity test

Measuring range
Buzzer
Off-load voltage: ~1.2 V
Overload protection: 250 V DC or 250 V AC RMS

Diode test

Measuring range
Diode
Supply current: ~1 mA DC
Supply voltage: ~3.3 V DC
Overload protection: 250 V DC or 250 V AC RMS

Capacity measurement

Measuring range
6 µF
60 µF
600 µF
6 mF
60 mF
Overload protection: 250 V DC or AC RMS
®
Testboy
TV 216N
Resolution
0.1 
Resolution
0.001 V
Resolution
0.001 µF
0.01 µF
0.1 µF
1 µF
10 µF
Function
The sensor sounds up to
30 Ohm
Function
The diode supply voltage is
displayed
Tolerance
< 2 µF ± (4.0 % + 5 digits)