Filter element servicing
During servicing, the external surfaces of the filter assembly
must be cleaned to remove any dust deposits.
Servicing must be conducted using suitable tools that do not
present a hazard.
Servicing must not be carried out when a potentially explosive
atmosphere is present.
CAUTION:
Filter elements should be replaced upon indication or
at specified intervals, six months maximum. Failure
to change the element will cause the filter to go on
bypass.
Refer to Service Parts List (Section 9) for item numbers for
applicable replacement element series. Remove and replace
element as follows:
7.1
Turn off and depressurize the system. Open vent plug
(5) at top of filter one and one-half turns.
WARNING:
FAILURE TO DEPRESSURISE THE FILTER
BEFORE SERVICING ELEMENT COULD RESULT
IN EXPLOSIVE LOSS OF FLUID, DAMAGE TO
EQUIPMENT AND POSSIBLE PERSONAL INJURY.
7.2
Open drain plug (5) at the bottom of the bowl and drain
fluid from the bowl into a suitable waste receptacle.
Replace and torque tighten drain plug to 12 ft/lb or 16 Nm.
Unscrew and remove the bowl (2) from head (1) counter-
clockwise when viewed from below.
7.3
Element replacement (UE210 Series): Remove filter
element (8), if already fitted, and carefully inspect the
interior surface (flow through the element is in-to-out) for
visible contamination. Normally no dirt should show, but
visible dirt or particles can be an early warning of system
component failure. Discard both the filter element
and its O-ring. The filter element is NOT CLEANABLE.
Any attempt to clean the filter element can cause
degradation of the filter medium and allow contaminated
fluid to pass through the filter element.
WARNING:
DO NOT ATTEMPT TO CLEAN OR RE-USE THE
ELEMENT.
ONLY USE GENUINE PALL REPLACEMENT FILTER
ELEMENTS. USE OF SUBSTITUTE ELEMENTS MAY
INVALIDATE PRODUCT WARRANTY.
UR210 Series
s e r v i c e i n s t r u c t i o n s
7.4
DO NOT run the system without a filter element
installed. Check that the O-ring (3) between the bowl (2)
and head (1) is not damaged. Use the replacement filter
as indicated by the part number on the element endcap.
7.5
Lubricate element O-ring with clean system fluid.
Reinstall element in the shell assembly. Lightly lubricate
bowl to head O-ring with clean system fluid and
reassemble the housing until thread bottoms. Tighten to
10-14LBFT (13-19Nm).
7.6
Bleed the filter by filling the filter until all air bleeds
through the vent plug(7), then torque tighten the vent
plug to 12 lb/ft or 16Nm. Check for leaks as per
section 4.8.
7.7
After element change ENSURE DIFFERENTIAL
PRESSURE DEVICE IS RESET. Brass visual and
electrical and stainless steel electrical switches reset
automatically. When system reaches normal operating
temperature, check that the electrical switch and/or
visual warning button/flag has not actuated. If visual
indicator actuates due to a cold start condition, reset
again as per section 6.
8
Warranty, Limitation of Liability
and Remedies
THERE IS NO WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WITH RESPECT
TO ANY OF THE PRODUCTS, NOR IS THERE ANY OTHER
WARRANTY EXPRESS OR IMPLIED, EXCEPT AS PROVIDED
FOR HEREIN.
For a period of twelve months from the date of delivery
from Seller or three thousand hours of use, whichever
occurs first (the "Warranty Period"), Seller warrants that
products manufactured by Seller when properly installed
and maintained, and operated at ratings, specifications and
design conditions, will be free from defects in material and
workmanship. By way of explanation and not limitation, the
Seller does not warrant the service life of the filter element
as this is beyond the Seller's control and depends upon
the condition of the system into which the filter is installed.
Seller's liability under any warranty is limited solely (in Seller's
discretion) to replacing (FOB original ship point), repairing
or issuing credit for products that become defective during
the Warranty Period. Purchaser shall notify Seller promptly in
writing of any claims and provide Seller with an opportunity to
inspect and test the product claimed to be defective. Buyer
shall provide Seller with a copy of the original invoice for the
product, and prepay all freight charges to return any products
to Seller's factory, or other facility designated by Seller. All
claims must be accompanied by full particulars, including
system operating conditions, if applicable.
Seller shall not be liable for any product altered outside of the
Seller's factory except by Seller or Seller's authorized distributor,
and then, as to the latter, only for products which have been
assembled by the distributor in accordance with Seller's written
instructions. Nor shall Seller be liable for a product subjected
to misuse, abuse, improper installation, application, operation,
maintenance or repair, alteration, accident or negligence in use,
storage transportation or handling.
In no event will Seller be liable for any damages, incidental,
consequential or otherwise, whether arising out of or in
connection with the manufacture, packaging, delivery, storage,
use, misuse, or non use of any of its products or any other
cause whatsoever.
4