Maintenance
To ensure the device's cooling mechanism functions properly for longer periods of time,
regularly perform the following maintenance steps:
o Disconnect the device from its power source by removing the plug from its socket.
o Open the channel at the front-right of the device to access the condenser.
HOT SURFACE! Danger of burns!
The condenser's surface can get hot during normal use.
Do not touch it with bare hands.
o Delicately clean the condenser with a vacuum or brush.
o Close the channel after cleaning.

7. Possible Malfunctions

In case of malfunction, disconnect the device from its power source. Before contacting
the service or sales agent, verify - based on the table below - whether it is possible to
eliminate disruption in operation.
Problem
No cooling
Insufficient
cooling power
- 38 -
Cause
• Plug improperly
connected.
• Safety fuse activated.
• Power outage
• Damaged temperature
regulator.
• Direct sunlight or heat
source nearby.
• Poor air circulation inside
the device.
• Food stored in device is
too warm.
• Device is overfilled.
Removal
• Remove plug and reconnect
properly.
• Check fuse, check device after
connecting to another outlet.
• Check power source
• Call a service center or sales
agent.
• Separate device from heat
source.
• Ensure sufficient distance from
walls and other objects.
• Cool food products before
placing inside device.
• Do not overfill device, remove
excess products.