STEP 3
Install the Kitchen Faucet dapter
NOTE: The Kitchen Faucet dapter is designed to fit 1/2" NPTF supply threads.
1
Locate the cold water shut-off valve under the sink. Turn off the cold water supply to the sink.
NOTE: If uncertain about which line supplies the cold water, turn on the hot water to the faucet. llow the water to heat up and carefully
feel the pipes under the sink. The pipe that remains cool to the touch is the cold water supply.
2
Turn on the kitchen faucet to release pressure and allow water to completely drain from the line.
3
Disconnect the cold water line from the 1/2" threaded stem on the bottom of the kitchen faucet.
NOTE: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw to accommodate the
Kitchen Faucet dapter.
4
Holding the Kitchen Faucet dapter
5
Screw the cold water supply line to the male threads of the Kitchen Faucet dapter using the nut that was connecting the cold
water line to the kitchen faucet previously. For a secure fit, tighten the nut using an adjustable wrench.
6
If you have replaced your sprayer with the Faucet for Filtered Water be sure to cap off the sprayer outlet from the kitchen faucet.
Most faucets will require a compression cap to seal and prevent leaks.
Be sure that all electrical appliances and outlets are turned off at the
circuit breaker before working in cabinet area.
STEP 4
Mount the System Head
1
Choose an easy-to-access area under the sink to mount the Filter System.
NOTE: To allow adequate space for filter changes, allow a minimum clearance of 4-6" below the QuickTwist
must be mounted in a vertical position.
NOTE: Mount the Filter System to a solid cabinet wall or wall. If a solid surface is not available, use hollow-wall anchor bolts or toggle
bolts (not included) to secure to the wall.
2
Remove the cap from the top of the System Head
provided on the back of this booklet, mark the holes for the Mounting Screws
3
Using a 1/8" drill bit, drill two pilot holes for the Mounting Screws. Insert Mounting Screws into the wall with a Phillips screwdriver,
leaving approximately 3/8" of each Mounting Screw exposed.
4
Hang the System Head on the eyes of the bracket and replace the System Head cap.
WFQT13000 & WFQT13500 Series
H
in an upright position (see diagram), screw onto the threaded faucet stem.
W RNING
. Using the Built-in Bracket on the back of the System Head or the template
C UTION
Please wear safety glasses to protect
eyes when drilling.
Filter. The Filter System
™
C
on the wall surface.
6
3
KITCHEN F UCET
4
H
3
5
HOT W TER
COLD W TER
V LVE
X
X
4
INLET
4-6"
2
1
V LVE
RIGID PIPE INST LL TION
2
OUTLET
3