16. Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and crimp
a yellow fork terminal (P, Figure 14, Ref. 7) onto the
wire.
14
P
17. Loosen the screw on AC post 2 of 725 light relay 1 and
connect the new fork terminal on the wire (Q, Figure
15) removed from either Zettler relay 1 or 2 into the
post. Tighten down the screw onto the fork terminal.
15
18. Take the two cut 10 AWG wires (R, Figure 16) that
were set aside in Step 9 and crimp a yellow fork
terminal (S, Figure 16, Ref. 7) on one of the ends of
each wire. On the other end of each wire, crimp on the
terminal ring (T, Figure 16, Ref. 6).
16
T
725 Relay 1
Q
R
S
19. If working from Zettler relay 2, install the terminal ring
end of one of the new assembled 10 AWG wires (U,
Figure 17a-b) onto the top of light switch 4 by using
one the screws that were removed in Step 12. Install
the terminal ring of the other new assembled wire (V,
Figure 17a-b) onto the top of light switch 6 If working
from Zettler relay 1, install wires onto light switch 3 and
5 (Not Shown). Make sure screw is tightened down on
the ring terminal.
17a
Light Switch 1
Light Switch 5
Light Switch 3
Light Switch 2
Light Switch 4
17b
Light Switch 4
Light Switch
Connection Detail
U
V
Light Switch 6
U
Light Switch 6
en
English
V
7