Water softener ELETTRONIC with AUTOTROL digital head logix
PROCEDURES FOR MANUAL REGENERATION
To start manual regeneration:
• Press and immediately release the button REGENERATE once for delayed regeneration.
The system will regenerate at the next set time (2:00).
A flashing regeneration symbol will appear
• Keep the button REGENERATE pressed for 5 sec to immediately start the manual regeneration.
A regeneration symbol will appear.
• After immediate regeneration starts, press REGENERATE again in order to start the second manual
regeneration.
The symbol X2 will appear, informing that the first regeneration will be followed by a second one.
During regeneration:
• "C" followed by a number shows the current cycle.
• The total remaining time for regeneration is shown on the display.
• Keep SET pressed to see the remaining time for the current cycle.
To scroll the regeneration cycles:
• Keep SET pressed – it shows the current time;
• Simultaneously press and release SET and UP in order to proceed with the cycle. During the cam
operation a sundial will appear. When the cam reaches the next cycle, "C2" will appear.
• Press and release SET and UP again in order to proceed with the cycle.
• Keep SET and UP pressed for 5 sec to cancel regeneration. The sundial will flash when the
cancellation has been completed.
The camshaft will proceed towards the initial position – it may take 1-2 minutes.
Regeneration cycles:
C1 – Counter-washing
C2 – Regenerating agent suction/slow rinse (not used in filter mode)
C3 – Slow rinse (not used in filter mode)
C4 – System pause (to re-pressurize the bottle)
C5 – Fast rinse cycle
C6 – II° counter-washing cycle (not used in filter mode) –
C7 – II° fast rinse cycle (not used in filter mode) –
C8 – Filling the regenerating tub (not used in filter mode)
________________________________________________________________________________
24
.
Regeneration
symbol
Cycle
indicator