Water softener ELETTRONIC with AUTOTROL digital head logix
PROBLEMS
The programmer stops during the
regeneration cycle
Softener regenerates continuously
The programmer does not regenerate
automatically or when the start up
button is pushed
The programmer does not regenerate
automatically but only by pushing the
start button
Lack of softened water between two
regenerations
34
CAUSES
Burn out engine
Incorrect voltage or frequency
Incorrect voltage or frequency
The camshaft is blocked
Excessive supply pressure
Fiber-optic player wrong placed
Detective camshaft
Detective timer
Power supply disconnected
Damaged or burnt out engine
Damaged or burnt out timer
Wrong timer setting
Defective printed circuit board
Hardness and capacity unset
Counting cable incorrectly inserted in
the turbine
External by pass valve open
Incorrect regeneration
Polluted resins
Wrong set up of the quantity of salt
Wrong setting of hardness or cyclic
capacity
Hardness has increased
Obstructed output
SOLUTIONS
Replace the engine
Check the right voltage or frequency
Check the right voltage or frequency
Remove damaging bodies from the
valve or from the camshaft
Install a pressure regulator
Place fiber-optic player in the right place
Replace the camshaft
Replace the timer
Connect
Replace engine
Replace timer
Reset the timer according to the
softener model referring to the values
shown in the column in the chart
Replace programmer
Check
Put the bayonet insert of counting
cable in the turbine section
Close the by pass valve
Repeat regeneration being sure to use
the right quantity of salt
Wash or replace resins
Check and set up again
Check and reset
Check and reset
Remove impurities to let turbine runs
without problems