LF ELETTRONIC Manual De Instrucciones página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

TIMER RESET PROCEDURE
IMPORTANT
Perform reset procedure only if recommended by the supplier, the manufacturer or, ideally,
be assisted directly by a skilled technician, also on the phone.
To reset the timer:
1 - Keep SET and DOWN simultaneously pressed for 5 seconds.
2 - H0 and the programme set by the system (7÷16/F) will be
displayed.
3 - If a historical value other than "H0" is shown, use the arrow UP
to scroll the settings until "H0" appears.
4 - To reset the timer, keep SET pressed for 5 seconds.
5 - The timer will be reset at a non-programmed state.
6 - Go to "initial setting" section to re-programme the timer.
WARNING
Timer reset will erase all recorded information. This means that it will be necessary to
completely re-programme the timer from initial starting mode.
For further information about the equipment performance, see the Manufacturer's Manual of
instructions, use and maintenance.
________________________________________________________________________________
INSTRUCTIONS FOR THE INSTALLATION OF RESIN DISINFECTION SYSTEM
Programmers Logix 740C/742C e 760C/762C are conceived in order to control a device for the
production of chlorine (optional), which allows to disinfect the resin bed after each regeneration.
There is an alert indication for lack of salt. The installation of the chlorinator is simple.
Step 1
Remove timer Logix from the valve and take power off.
Water softener ELETTRONIC with AUTOTROL digital head logix
25

Publicidad

Tabla de contenido
loading

Tabla de contenido