Descargar Imprimir esta página

Vimar ELVOX 6328 Manual De Instrucciones página 4

Ocultar thumbs Ver también para ELVOX 6328:

Publicidad

Kit Due Fili
TERMINALS OF MONITOR TYPE 6328, 6328/C OR 6328/CD
1,2)
BUS Line
3,4)
For connection of additional chime type 860A (see variation 1)
12, 13) Additional power supply art. 6923 (terminal 12 = positive)
V3, M) connection for outdoor call push-button.
PROGRAMMING OF MONITOR TYPE 6328, 6328/C OR 6328/CD
5
4
3
2
1
Monitor identification code
ID1 ID0 MONITOR
ID 0
n°1
ID 1
n°2
n°3
n°4
Lock release
Removing contact 3 from the monitor it is possible to open the door lock
always, with monitor switched off or switched on. Inserting the jumper, it is
possible to release the door lock from the monitor only after the call.
Association of call push-button from the entrance panel
To associate the entrance panel push-button with which to call and switch on
the monitor, operate on contacts 4 and 5: contact 4 for the right hand panel
push-button or 1° push-button and contact 5 for the left hand push-button or
2° push-button. Inserting the jumpers the call is excluded, removing them the
call and the monitor activation is enabled.
4 5
CH2
CH1
4 5
CH2
CH1
4
The operation of monitor type
6308 is managed by the 5 con-
tact setting on the back of mon-
itor. To activate the functions
insert or remove the jumpers
supplied with monitor.
Programming must be carried
out before powering the instal-
lation.
1 2
When on the intallation there is
more than one monitor it is nec-
essary to identify the monitor
with a different code. The iden-
tification code is assigned by in-
serting the jumpers in contacts 1
and 2 (ID0 and ID1) as indicated
in the figure.
VIDEO SIGNAL STABILISATION
If an image on the monitor is misshaped, displace jumper, placed on the
monitor fixing plate (R684, R682), to one of the following alternative positions
"B" or "C".
On installations where several monitors are
connected in series between them, place only
the jumper of last monitor to the "B" or "C"
position and kepp the other jumpers of other
monitors in the "A" position.
On installations with more monitors con-
nected in star configuration, place the jumper
to the "B" or "C" position only on the monitor
with misshaped image.
MONITOR INSTALLATION (FIG. 1-2, Page 11)
- The monitor should be installed far away from sources of light, heat and
electrical disturbances.
- Fix metal hooking plate to the wall with fixing screws supplied, keeping top
of panel at 1,40 m. from ground level.
- A drilling is forseen in order to fix the plate to a module flush-mounted back
box.
- Carry out connections on monitor terminal block following the diagrams.
- Hook the monitor following the arrow 1 and 2 direction .
- To remove the monitor from the hooking plate, operate with a screwdriver
on the security lock and remove it following the arrows 1 and 2 in the oppo-
site direction.
The monitor can be transformed into desk-top version by using the proper
conversion kit type 661A (Fig. 4, page 11).
CONNECTIONS
The two connecting wires between power supply and monitor can be inverted.
- The advised section for the two conductors is of 0,75 mm² (twisted pair).
The following features cannot be guaranted if the section is different.
- The installation is guaranted for a good operation with 100 m maximum
distance from the power supply to the monitor.
- In any case the maximum distance between the camera and the monitor
must not exceed 120 m.
- The electric lock connected to the installation must have a maximum of 1A
power consumption with 12V voltage.
- Humming sounds or electrical discharges may affect the appliance good
operation.
Operating dwell time:
The monitor, camera, door lock and auxiliary services mut operate according
to the following intermittent cycles.
Monitor and camera activation cycle:
max. 90 seconds activated, 90 seconds deactivated
Door lock cycle:
max. 30 seconds activated, 150 seconds deactivated
Auxiliary service cycle:
max. 90 seconds activated, 90 seconds deactivated
INSTALLATION RULES.
Installation should be carried out observing current installation regulations for
electrical systems in the Country where the products are installed.
CONFORMITY.
EMC directive
Standards EN 61000-6-1, EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE 2002/96 (WEEE)
In order to avoid damage to the environment and human health as
well as any administrative sanctions, any appliance marked with this
symbol must be disposed of separately from municipal waste, that
is it must be reconsigned to the dealer upon purchase of a new one. Appli-
ances marked with the crossed out wheelie bin symbol must be collected in
accordance with the instructions issued by the local authorities responsible
for waste disposal.