1735
Getting Started
21 Switch between the individual events (if there is more than one).
This is also possible if the recording has been stopped and you want to
evaluate the stored events.
Hold/Run and Save/Enter functionality is explained earlier in this manual.
Logged Events
You can download logged events using Power Log software.
Power Log software presents the event data in a variety of formats:
•
graphs similar to those displayed on the instrument
•
statistical format with number of events, range of duration and range of
voltage
•
spreadsheet format with date/time stamp, event type and duration
Harmonics
Select Harmonics with the rotary switch.
In this measuring mode you can determine the Harmonics H1 (fundamental
frequency) to H50 for all phases (L1, L2, L3) of:
•
Voltage (V)
•
Current (I)
24
edx029.bmp