DIMENSIONS mm
3/4" Ø heating delivery
3/4" Ø heating return
1/2" Ø cold water inlet
1/2" Ø hot water outlet
3/4" Ø gas inlet
TECHNICAL FEATURES
Thermal capacity
MODEL
Output
Input
50/30ºC
kW kcal/h kW kcal/h
FUTURIA 24
25 21.500 25,75 22.145
PLUS MB W TOP
Boiler version: mod. C type C13-C33-C43-C53-C83
Category: I 2H
Heating circuit operating pressure max. 3 bars
Hot water circuit operating pressure max. 6 bars
CIRCULATING PUMP FEATURES
Delivery/pressure available at the system
All manuals and user guides at all-guides.com
Min. thermal capacity
Output
Input
80/60ºC
kW kcal/h
kW kcal/h kW kcal/h
24,5 21.070
8,8 7.568 9,33 8.022
Hot water supply
Output
Output
Water
supply
50/30ºC
80/60ºC
∆30ºC
kW kcal/h
l/h
8,98 7.719
680 145
Max. water temperature 90°C
Rated gas pressure: Natural gas 20 mbars
Expansion
tanks
Peak flow
Water-
Hot
Reset
Heating
over first
heater
water
10 min.
capacity
l
min.
l
l
l
10
90
3 89
8
35
Weight
kg