Activating Heating; Activating Cooling - Steinbach Waterpower 5000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 145
- Ensure that the grille on the heat exchanger is never covered
over and air can flow freely through the device.

Activating heating

The adjustable temperature range in heating operating mode is 5 – 45 °C. However, the
set water temperature must not differ more than 15 °C from the ambient temperature;
otherwise an error message appears on the display
activated, the start value of the set water temperature is 25 °C.
The water in the pool is heated up fastest at maximum throughput of the
water through the heat pump (see "Technical data" section). However,
increasing the flow rate reduces the time spent at the heat exchanger, which
means that the difference in temperature between the water in the pool and
the heated water at the pool inlet is lower overall and therefore less
noticeable. Please measure and record the change in the current water
temperature every 30 minutes to determine the actual heating of the pool
water.
Activating the heating operating mode
1. Open the protective cover over the display
2. Put the heat pump into standby mode (see "Display" section).
3. Press the ON/OFF button
4. Repeatedly press the Mode button
The Heating indicator
Setting the temperature
1. Repeatedly press the Down button
After the temperature is set, it can take up to 3 minutes until the heat pump starts
up.
The Temperature 1 display

Activating cooling

The adjustable temperature range in cooling mode is 5 – 45 °C. However, the set water
temperature must not differ more than 15 °C from the ambient temperature; otherwise
an error message appears on the display
the start value of the set water temperature is 30 °C.
Activating cooling operating mode
1. Open the protective cover over the display
2. Put the heat pump into standby mode (see "Display" section).
3. Press the ON/OFF button
.
18
17
appears. The heat pump is in heating operating mode.
20
15
shows the desired water temperature in °C.
24
.
18
. After heating operating mode is
C
.
C
.
or the Up button
. After cooling operating mode is activated,
C
.
C
.
16