Inspection; Checking The Gas Pressure (Manometer) - Steinbach Waterpower 5000 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 145

Inspection

Check the following before every use:
- Is there evidence of damage to the device?
- Is there evidence of damage to the controls?
- Are the accessories in proper condition?
- Are the supply lines and wiring in proper condition?
- Are the ventilation openings free and clean?
Do not put a damaged device or accessory into operation. Have it inspected and repaired
by the manufacturer, the manufacturer's customer service or a qualified specialist.
Risk of fire and explosion through leaking finned heat exchanger!
The coolant circuit of the finned heat exchanger contains highly
pressurised, easily flammable, odourless gas. Risk of fire and
explosion in the event of uncontrolled coolant leaks.
- Keep the heat pump away from heat sources and naked flames.
- Do not drill into or scorch the heat pump.
- Do not use any objects apart from those permitted by the
manufacturer to speed up the defrosting process.
- Immediately shut off the heat pump if you suspect a coolant leak.
- The coolant is odourless. Always keep ignition sources away from
the installation site of the heat pump.
- Contact an authorised expert if you suspect a coolant leak.
- Observe the national regulations on gas.
- All persons involved in work on the refrigerant circuit must have a
valid certificate from an industry accredited certification body
that ensures competence in handling refrigerants according to a
specific assessment recognized by industry associations.

Checking the gas pressure (manometer)

The manometer
7
fin heat exchanger, thus providing the heat pump with information about the coolant
status during operation.
64
measures the pressure of the gas phase in the coolant circuit of the
WARNING!