Connecting the DMX connection cable
How to proceed:
B, C
Remove the protection cap from the unit.
Fit the connector of the connection cable and secure with the two screws (max. 2.0 Nm).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
– Only connect the plug to the left-hand DMX/RDM socket.
AMX0034
Start-up
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (En-
vironmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.
Switching on the pump
Connect the unit to the power supply.
Switch on the pump with AquaMax Eco Control.
– The unit switches on as soon as the power connection is established.
Switching off the pump
Switch off the unit with the AquaMax Eco Control.
Disconnect the unit from the power supply
Remedy of faults
Malfunction
Pump does not start
Pump does not deliver.
Insufficient delivered quantity
Pump switches off after a short running period.
Note!
The device will be destroyed if water penetrates the DMX/RDM sockets.
Ensure that the DMX/RDM sockets are closed off by the DMX/RDM plug or protection
cap.
Cause
No mains voltage
Excessively soiled water
The impeller unit is blocked
Impeller unit is running sluggishly
Excessive loss in the supply lines
Excessively soiled water
Water temperature too high
The impeller unit is blocked
Pump has run dry.
Remedy
Check the mains voltage.
Check supply lines.
Clean the pump. The pump automatically
switches on again once the motor has cooled
down.
Disconnect the power supply and remove
obstacle. Then switch the pump on again.
Clean
Select larger hose diameter
Reduce hose length to reduce frictional loss
Avoid unnecessary connection elements
Clean the pump. The pump automatically
switches on again once the motor has cooled
down.
Note maximum water temperature of +35°C.
The pump automatically switches on again
once the motor has cooled down.
Disconnect the power supply and remove
obstacle. Then switch the pump on again.
Flood the pump. Fully submerge the pump
for operation in the pond.
- EN -