DC voltage measurement
Range
500.00 mV
5.0000 V
50.000 V
500.00 V
1000.0 V
Input impedance: 10 MΩ
Overload protection: 1000 V DC/AC RMS
Resistance measurement
Range
400.00 Ω
4.0000 kΩ
40.000 kΩ
400.00 kΩ
4.0000 MΩ
40.000 MΩ
Overload protection: 1000 V DC/AC RMS
Capacitance measurement
Range
500.00 nF
5.0000 µF
50.000 µF
500.00 µF
5.0000 mF
Overload protection: 1000 V DC/AC RMS
Resolution
0.01 mV
0.0001 V
0.001 V
0.01 V
0.1 V
Resolution
0.01 Ω
0.0001 kΩ
0.001 kΩ
0.01 kΩ
0.0001 MΩ
0.001 MΩ
Resolution
0.01 nF
0.0001 µF
0.001 µF
0.01 µF
0.0001 mF
CMP-3000 – USER MANUAL
Accuracy
 (0.1% m.v. + 4 digits)
 (0.2% m.v. + 5 digits)
Accuracy
 (1.0% m.v. + 9 digits)
 (1.0% m.v. + 4 digits)
 (2.0% m.v. + 9 digits)
 (3.0% m.v. + 10 digits)
Accuracy
 (3.5% m.v. + 40 digits)
 (3.5% m.v. + 9 digits)
 (5.0% m.v. + 9 digits)