Intended use
DC voltages from 6 V to 1400 V and AC voltages
from 6 V to 1000 V can be measured relative to
earth.
Likewise polarity, phase sequence and continuity
checks up to 200 kΩ as well as RCD tests can be
performed.
Thanks to its high degree of protection (IP65),
Multi-Tester Pro-LED can be used even under tough
operating conditions.
The device is only intended for use by electricians
and qualified personnel.
Any other use is considered improper.
The user is solely responsible for damage
resulting from improper use while any
warranty claims against the manufacturer
will likewise become invalid.
Device elements
General view (Fig. I)
1 Test probe L1
2 Physical markings
3 FI/RCD buttons
4 Handles
5 Test probe L2
6 LED indicators
7 LH button
Technical Data
Item
0715 53 165
Display
16 LEDs for voltage (12,
24, 48, 120, 230, 400,
690 and 1000 V), polarity
(+~-), continuity (Rx/Ω)
and phase/rotary field (R/L)
+ELV
Nominal voltage
6 ... 1000 V/AC
6 ... 1400 V/DC
Indication
0.85 Un
Frequency range
0.16 ... 500 Hz
Switchable load
30 mA at 230 V
Cyclic duration
30 s ON/240 s OFF
factor
Rated current I
< 3.5 mA
N
Peak current I
< 0.3 A with button pressed
P
(FI/RCD)
Line conductor test
> 100 V/AC
pole
Protection class
II
Impedance
625 kΩ / 5 kΩ for ELV AC
voltage
Continuity test
0 ... 200 kΩ
Climatic category
N normal
Operating tempera-
-15 °C to +45 °C, at
ture
> 95 % to +31 °C
Degree of protec-
IP 65
tion
Overvoltage
CAT IV 1000 V
category
Test standard
EN 61234-3:2014
Power supply
2 x 1.5 V type AAA Micro
Item 0827 111
11