5. Table of errors
Error code
EP 1
EP 2
E1 LO
temperature of probe T1 is too low (below 0
E1 HI
temperature of probe T1 is too high (above 110
E2 LO
temperature of probe T2 is too low (below 0
E2 HI
temperature of probe T2 is too high (above 110
E3 LO
temperature of probe T3 is too low (below 0
E3 HI
temperature of probe T3 is too high (above 110
E4
Et
E1
E2
safety temperature exceeded – error displayed after the completion of emergency rinsing
6. Start-up of the device
Turn on the switch located on the wall, open the dishwasher door, place the overflow plug in the appropria-
te place (fig. 8) and close the door of the device. Press the
boiler are filled with water, the boiler heating element will start operation. After the heating of water in
the boiler is completed, the dishwasher chamber water heating cycle will begin. Insert the basket into the
device chamber and wait until the water in the chamber reaches the set temperature. Before starting the
wash cycle, it is necessary to select the program. The wash cycle is activated automatically by opening and
closing the dishwasher door. If the door is opened during the wash cycle, the program stops automatically.
After the door is closed, the program continues the wash cycle. The completion of the wash cycle program is
indicated by a sound signal from the control board. Remove the basket from the device chamber.
Water for washing
Water for rinsing/sanitizing
7. Emptying of the tank in models equipped with a drain pump
Turn the device off by pressing the
plug and close the door. Turn the drain pump on using the
proceeds automatically until the tank is completely emptied of water. In order to reactivate the device, put
the overflow plug back in its place, close the door and press the On/Off switch. However, if the device will
not be used any more, turn the main switch off.
8. Emptying of the tank in models not equipped with a drain pump
Turn the device off by pressing the
plug and wait until the water is drained off completely from the tank. Put the overflow plug back in its place, close
the door of the device.
Do not turn the device off when the water is still in the tank. Before turning the device off, always empty the
tank of water. In the event the device will no longer be used, after the completion of the above and the possible
initiation of a regeneration cycle, it is necessary to turn the device off by pressing the switch. The main switch should
then be turned off and the water valve should be closed.
filling time exceeded, but a second attempt was undertaken
double filling time exceeded, attempts terminated
power outage during the operation of the dishwasher
temperature difference between probe T1 and T2 is too high (>30
switch , then open the door of the device, remove the overflow
the switch , then open the door of the device, remove the overflow
Error description
º
C) (or an open circuit in the probe)
º
C) (or a short circuit in the probe)
º
C) (or an open circuit in the probe)
º
C) (or a short circuit in the probe)
º
C) (or an open circuit in the probe)
º
C) (or a short circuit in the probe)
boiler overheating
switch button . After the tank and the
º
60-65
C (140-149
º
82-90
C (181-194
- 36 -
º
C)
°
F)
°
F)
button. The draining process