8022691.10DR | SICK
Subject to change without notice
WTB16x-xxxxxx2xAxx with press-turn element:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: sensing range increased.
Counterclockwise rotation: sensing range reduced.
The sensing range can also be adjusted using just the potentiometer. We recommend
placing the object within the sensing range, see figure 8 for an example. Once the sens‐
ing range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change
table
1,
table
2).
1
1...3 sec.
2
3
Figure 8: WTB16x-xxxxxx2xAxx, adjusting the sensing range with press-turn element
6
COMMISSIONING
(see
9